切换至 "中华医学电子期刊资源库"

中华关节外科杂志(电子版) ›› 2022, Vol. 16 ›› Issue (01) : 55 -60. doi: 10.3877/cma.j.issn.1674-134X.2022.01.009

综述

全膝关节置换术后关节不稳
李博1, 李冬松1, 李泽恒1, 成远强1, 冯卫1, 许岩1,(), 刘建国1   
  1. 1. 130012 长春,吉林大学第一医院骨关节外科
  • 收稿日期:2020-05-03 出版日期:2022-02-01
  • 通信作者: 许岩
  • 基金资助:
    吉林省自然科学基金(20190201057JC)

Instability following total knee arthroplasty

Bo Li1, Dongsong Li1, Zeheng Li1, Yuanqiang Cheng1, Wei Feng1, Yan Xu1,(), Jianguo Liu1   

  1. 1. Department of Arthroplasty, the First Hospital of Jilin University, Changchun 130012, China
  • Received:2020-05-03 Published:2022-02-01
  • Corresponding author: Yan Xu
引用本文:

李博, 李冬松, 李泽恒, 成远强, 冯卫, 许岩, 刘建国. 全膝关节置换术后关节不稳[J]. 中华关节外科杂志(电子版), 2022, 16(01): 55-60.

Bo Li, Dongsong Li, Zeheng Li, Yuanqiang Cheng, Wei Feng, Yan Xu, Jianguo Liu. Instability following total knee arthroplasty[J]. Chinese Journal of Joint Surgery(Electronic Edition), 2022, 16(01): 55-60.

人工全膝关节置换术(TKA)是目前治疗膝关节骨关节炎、膝关节类风湿性关节炎等膝关节疾病的主要术式,在减轻病变关节疼痛、改善关节功能方面具有良好的效果。TKA的目标就是恢复正常膝关节的功能和稳定,但在接受TKA的患者中,有高达20%的患者对术后效果不满意,关节不稳是引起患者术后不满意的主要原因之一。探讨关节不稳有利于改进产品的设计制造理念、提高产品性能,同时可以帮助手术医生优化手术技术、减小人为因素导致的关节不稳。影响关节不稳的因素众多,假体的影响(如假体设计、假体选择)、手术技术(如截骨误差、关节线水平)和患者因素(如年龄、性别、体重)等都对膝关节置换术后稳定性产生重要影响。关节不稳是膝关节翻修的一个常见指征,大多数保守治疗无效,因此应通过优化假体设计、提高手术技术、指导患者康复等方法进行预防,必要时行翻修手术。

Total knee arthroplasty(TKA) is currently the main surgical method for the treatment of knee osteoarthritis, rheumatoid arthritis and other knee diseases. It has a good effect in reducing the pain of diseased joints and improving joint function. The goal of TKA is to restore normal knee function and stability. However, among patients receiving TKA, up to 20% of patients are dissatisfied with the postoperative effect, and joint instability is one of the main causes of postoperative dissatisfaction. Discussing joint instability is helpful to improve product design and manufacturing concepts and improve product performance. At the same time, it can help surgeons optimize surgical techniques and reduce joint instability caused by human factors. There are many factors that affect joint instability. The impact of prosthesis (such as prosthesis design, prosthesis selection), surgical technique (such as osteotomy error, joint line level) and patient factors (such as age, gender, weight), etc. The stability after joint replacement has an important impact. Joint instability is a common indication for knee revision, and most conservative treatments are ineffective. Therefore, it should be prevented by optimizing the design of the prosthesis, improving the surgical technique, and guiding the rehabilitation of the patient.

表1 全膝关节置换术后关节不稳的影响因素
[1]
Ethgen O, Bruyère O, Richy F, et al. Health-related quality of Life in total hip and total knee arthroplasty. A qualitative and systematic review of the literature[J]. J Bone Joint Surg Am, 2004, 86-A(5): 963-974.
[2]
Kurtz S, Ong K, Lau E, et al. Projections of primary and revision hip and knee arthroplasty in the United States from 2005 to 2030[J]. J Bone Joint Surg Am, 2007, 89(4): 780-785.
[3]
Ewing JA, Kaufman MK, Hutter EE, et al. Estimating patient-specific soft-tissue properties in a TKA knee[J]. J Orthop Res, 2016, 34(3): 435-443.
[4]
Garvin KL, Wright TM. Strategies to improve total knee arthroplasty: a multidisciplinary research conference[J/OL]. J Am Acad Orthop Surg, 2017, 25 Suppl 1: S1-S3. DOI: 10.5435/JAAOS-D-16-00633.
[5]
Calliess T, Ettinger M, Hulsmann N, et al. Update on the etiology of revision TKA-Evident trends in a retrospective survey of 1449 cases[J]. Knee, 2015, 22(3): 174-179.
[6]
Petrie JR, Gj H. Instability in total knee arthroplasty[J].Bone Joint J, 2016, 98B(1): 116-119.
[7]
Cottino U, Sculco PK, Sierra RJ, et al. Instability after total knee arthroplasty[J]. Orthop Clin North Am, 2016, 47(2): 311-316.
[8]
Miyasaka KC, Ranawat CS, Mullaji A. 10- to 20-year followup of total knee arthroplasty for valgus deformities[J]. Clin Orthop Relat Res, 1997, (345): 29-37.
[9]
Yoshihara Y, Arai Y, Nakagawa S, et al. Assessing coronal laxity in extension and flexion at a minimum of 10 years after primary total knee arthroplasty[J]. Knee Surg Sports Traumatol Arthrosc, 2016, 24(8): 2512-2516.
[10]
Jones DP, Locke C, Pennington J, et al. The effect of sagittal laxity on function after posterior cruciate-retaining total knee replacement[J]. J Arthroplasty, 2006, 21(5): 719-723.
[11]
Watanabe T, Koga H, Katagiri H, et al. Coronal and sagittal laxity affects clinical outcomes in posterior-stabilized total knee arthroplasty: assessment of well-functioning knees[J]. Knee Surg Sports Traumatol Arthrosc, 2020, 28(5): 1400-1409.
[12]
Edelstein A, Bhatt S, Wright-Chisem J, et al. The effect of implant design on sagittal plane stability: a randomized trial of medial-versus posterior-stabilized total knee arthroplasty[J]. J Knee Surg, 2020, 33(5): 452-458.
[13]
Song SJ, Park CH, Bae DK. What to know for selecting Cruciate-Retaining or posterior-stabilized total knee arthroplasty[J]. Clin Orthop Surg, 2019, 11(2): 142-150.
[14]
Rodriguez-Merchan EC. Instability following total knee arthroplasty[J]. HSS J, 2011, 7(3): 273-278.
[15]
Sierra RJ, Berry DJ. Surgical technique differences between posterior-substituting and cruciate-retaining total knee arthroplasty[J]. J Arthroplasty, 2008, 23(7 Suppl): 20-23.
[16]
In Y, Kim SJ, Kim JM, et al. Agreements between different methods of gap balance estimation in cruciate-retaining total knee arthroplasty[J]. Knee Surg Sports Traumatol Arthrosc, 2009, 17(1): 60-64.
[17]
Gustke KA, Gj G, Roche MW, et al. Increased satisfaction after total knee replacement using sensor-guided technology[J]. Bone Joint J, 2014, 96-B(10): 1333-1338.
[18]
Elmallah RK, Mistry JB, Cherian JJ, et al. Can we really " feel" a balanced total knee arthroplasty? [J]. J Arthroplasty, 2016, 31(9 Suppl): 102-105.
[19]
Nielsen ES, Hsu A, Patil S, et al. Second-generation electronic ligament balancing for knee arthroplasty: a cadaver study[J]. J Arthroplasty, 2018, 33(7): 2293-2300.
[20]
Kahlenberg CA, Elmasry S, Mayman DJ, et al. Posterior condylar bone resection and femoral implant thickness vary by up to 3 mm across implant systems: implications for flexion gap balancing[J]. Knee Surg Sports Traumatol Arthrosc, 2019, 27(7): 2140-2144.
[21]
Luyckx T, Vandenneucker H, Ing LS, et al. Raising the joint line in TKA is associated with mid-flexion laxity: a study in cadaver knees[J]. Clin Orthop Relat Res, 2018, 476(3): 601-611.
[22]
Kadoya Y, Kobayashi A, Komatsu T, et al. Effects of posterior cruciate ligament resection on the tibiofemoral joint gap[J]. Clin Orthop Relat Res, 2001, (391): 210-217.
[23]
Yagishita K, Muneta T, Ikeda H. Step-by-step measurements of soft tissue balancing during total knee arthroplasty for patients with varus knees[J]. J Arthroplasty, 2003, 18(3): 313-320.
[24]
Griffin FM, Insall JN, Scuderi GR. Accuracy of soft tissue balancing in total knee arthroplasty[J]. J Arthroplasty, 2000, 15(8): 970-973.
[25]
Walker PS, Meere PA, Bell CP. Effects of surgical variables in balancing of total knee replacements using an instrumented tibial trial[J]. Knee, 2014, 21(1): 156-161.
[26]
Cross MB, Nam D, Plaskos C, et al. Recutting the distal femur to increase maximal knee extension during TKA causes coronal plane laxity in mid- flflexion[J]. Knee, 2012, 19(6): 875-879.
[27]
Sheth NP, Husain A, Nelson CL. Surgical techniques for total knee arthroplasty: measured resection, gap balancing, and hybrid[J]. J Am Acad Orthop Surg, 2017, 25(7): 499-508.
[28]
Luyckx T, Peeters T, Vandenneucker H, et al. Is adapted measured resection superior to gap-balancing in determining femoral component rotation in total knee replacement?[J]. J Bone Joint Surg Br, 2012, 94(9): 1271-1276.
[29]
Blakeney W, Beaulieu Y, Puliero B, et al. Bone resection for mechanically aligned total knee arthroplasty creates frequent gap modifications and imbalances[J]. Knee Surg Sports Traumatol Arthrosc, 2020, 28(5): 1532-1541.
[30]
Tapasvi SR, Shekhar A, Patil SS, et al. Comparison of gap balancing vs measured resection technique in patients undergoing simultaneous bilateral total knee arthroplasty: one technique per knee[J]. J Arthroplasty, 2020, 35(3): 732-740.
[31]
Whiteside LA, Saeki K, Mihalko WM. Functional medial ligament balancing in total knee arthroplasty[J]. Clin Orthop Relat Res, 2000, (380): 45-57.
[32]
Babazadeh S, Dowsey MM, Stoney JD, et al. Gap balancing sacrifices Joint-Line maintenance to improve gap symmetry: a randomized controlled trial comparing gap balancing and measured resection[J]. J Arthroplasty, 2014, 29(5): 950-954.
[33]
Walker LC, Clement ND, Ghosh KM, et al. What is a balanced knee replacement?[J]. EFORT Open Rev, 2018, 3(12): 614-619.
[34]
Huang T, Long Y, George D, et al. Meta-analysis of gap balancing versus measured resection techniques in total knee arthroplasty[J]. Bone Joint J, 2017, 99-B(2): 151-158.
[35]
Winiarsky R, Barth P, Lotke P. Total knee arthroplasty in morbidly obese patients [J]. J Bone Joint Surg Am, 1998, 80(12): 1770-1774.
[36]
Del Gaizo DJ, Della Valle CJ. Instability in primary total knee arthroplasty[J]. Orthopedics, 2011, 34(9): e519-e521.
[37]
Kang KT, Koh YG, Son J, et al. Comparison of kinematics in cruciate retaining and posterior stabilized for fixed and rotating platform mobile-bearing total knee arthroplasty with respect to different posterior tibial slope[J/OL]. Biomed Res Int, 2018: 5139074. DOI:10.1155/2018/5139074.
[38]
Hamai S, Miura H, Higaki H, et al. Evaluation of impingement of the anterior tibial post during gait in a posteriorly-stabilised total knee replacement [J]. J Bone Joint Surg Br, 2008, 90B(9): 1180-1185.
[39]
Kang KT, Kwon SK, Son J, et al. The increase in posterior tibial slope provides a positive biomechanical effect in posterior-stabilized total knee arthroplasty[J]. Knee Surg Sports Traumatol Arthrosc, 2018, 26(10): 3188-3195.
[40]
Okazaki K, Tashiro Y, Mizu-Uchi H, et al. Influence of the posterior tibial slope on the flexion gap in total knee arthroplasty[J]. Knee, 2014, 21(4): 806-809.
[41]
Seo SS, Kim CW, Kim JH, et al. Clinical results associated with changes of posterior tibial slope in total knee arthroplasty[J]. Knee Surg Relat Res, 2013, 25(1): 25-29.
[42]
Wilson CJ, Theodoulou A, Damarell RA, et al. Knee instability as the primary cause of failure following total knee arthroplasty (TKA): a systematic review on the patient, surgical and implant characteristics of revised TKA patients[J]. Knee, 2017, 24(6): 1271-1281.
[43]
Delanois RE, Mistry JB, Gwam CU, et al. Current epidemiology of revision total knee arthroplasty in the United States[J]. J Arthroplasty, 2017, 32(9): 2663-2668.
[44]
Meehan JP, Danielsen B, Kim SH, et al. Younger age is associated with a higher risk of early periprosthetic joint infection and aseptic mechanical failure after total knee arthroplasty[J]. J Bone Joint Surg Am, 2014, 96A(7): 529-535.
[45]
Tigani D, Fosco M, Amendola L, et al. Total knee arthroplasty in patients with poliomyelitis[J]. Knee, 2009, 16(6): 501-506.
[46]
Krackow KA, Weiss AP. Recurvatum deformity complicating performance of total knee arthroplasty. A brief note[J]. J Bone Joint Surg Am, 1990, 72(2): 268-271.
[47]
Kannan A, O′connell RS, Kalore N, et al. Revision TKA for flexion instability improves patient reported outcomes[J]. J Arthroplasty, 2015, 30(5): 818-821.
[48]
Rajgopal A, Panjwani TR, Rao A, et al. Are the outcomes of revision knee arthroplasty for flexion instability the same as for other major failure mechanisms?[J]. J Arthroplasty, 2017, 32(10): 3093-3097.
[49]
Mcauley JP, Engh GA. Constraint in total knee arthroplasty: when and what?[J].J Arthroplasty, 2003, 18(3/supp/S1): 51-54.
[50]
Gehrke T, Kendoff D, Haasper C. The role of hinges in primary total knee replacement[J]. Bone Joint J, 2014, 96B(A): 93-95.
[51]
Kouk S, Rathod PA, Maheshwari AV, et al. Rotating hinge prosthesis for complex revision total knee arthroplasty: a review of the literature[J]. J Clin Orthop Trauma, 2018, 9(1): 29-33.
[1] 林文, 王雨萱, 许嘉悦, 王矜群, 王睿娜, 何董源, 樊沛. 人工关节置换登记系统的研究进展[J]. 中华关节外科杂志(电子版), 2023, 17(06): 834-841.
[2] 闫文, 谢兴文, 顾玉彪, 雷宁波, 马成, 于文霞, 高亚雄, 张磊. 微小RNA与全膝关节置换术后深静脉血栓的研究进展[J]. 中华关节外科杂志(电子版), 2023, 17(06): 842-846.
[3] 黄子荣, 罗渝鑫, 杨文瀚, 陈小虎, 谢环宇, 朱伟民. 前交叉韧带重建对膝关节稳定性影响的研究进展[J]. 中华关节外科杂志(电子版), 2023, 17(06): 847-854.
[4] 樊绪国, 赵永刚, 杨砚伟. 腓骨在膝骨关节炎作用的研究观点[J]. 中华关节外科杂志(电子版), 2023, 17(06): 855-859.
[5] 贺敬龙, 尚宏喜, 郝敏, 谢伟, 高明宏, 孙炜, 刘安庆. 重度类风湿关节炎患者行多关节置换术的临床手术疗效[J]. 中华关节外科杂志(电子版), 2023, 17(06): 860-864.
[6] 孟繁宇, 周新社, 赵志, 裴立家, 刘犇. 侧位直接前方入路髋关节置换治疗偏瘫肢体股骨颈骨折[J]. 中华关节外科杂志(电子版), 2023, 17(06): 865-870.
[7] 王宏宇. 固定与活动平台假体在全膝关节置换术中的应用价值[J]. 中华关节外科杂志(电子版), 2023, 17(06): 871-876.
[8] 夏传龙, 迟健, 丛强, 连杰, 崔峻, 陈彦玲. 富血小板血浆联合关节镜治疗半月板损伤的临床疗效[J]. 中华关节外科杂志(电子版), 2023, 17(06): 877-881.
[9] 李善武, 叶永杰, 王兵, 王子呓, 银毅, 孙官军, 张大刚. 胫骨高位截骨与单髁置换的早期疗效比较[J]. 中华关节外科杂志(电子版), 2023, 17(06): 882-888.
[10] 李辉, 吴奇, 张子琦, 张晗, 王仿, 许鹏. 日间全膝关节置换术早期疗效及标准化流程探索[J]. 中华关节外科杂志(电子版), 2023, 17(06): 889-892.
[11] 金鑫, 谢卯, 刘芸, 杨操, 杨述华, 许伟华. 个性化股骨导向器辅助初次全髋关节置换的随机对照研究[J]. 中华关节外科杂志(电子版), 2023, 17(06): 780-787.
[12] 邓华梅, 袁札根, 曾德荣, 潘珊珊, 张葆青, 欧爱华, 曹学伟. 全膝关节置换术中气压止血带应用效果与影响因素分析[J]. 中华关节外科杂志(电子版), 2023, 17(06): 788-794.
[13] 张思平, 刘伟, 马鹏程. 全膝关节置换术后下肢轻度内翻对线对疗效的影响[J]. 中华关节外科杂志(电子版), 2023, 17(06): 808-817.
[14] 付庆鹏, 邓晓强, 高伟, 姜福民, 范永峰, 吴海贺, 齐岩松, 包呼日查, 徐永胜. 新型股骨测量定位器在全膝关节置换术中的临床应用[J]. 中华临床医师杂志(电子版), 2023, 17(9): 980-987.
[15] 李岩松, 李涛, 张元鸣飞, 李志鹏, 周谋望. 头戴式虚拟现实设备辅助全膝关节置换术后康复的初步研究[J]. 中华临床医师杂志(电子版), 2023, 17(06): 676-681.
阅读次数
全文


摘要